Last Modified: 11-29-2007 1.6 U
Service Category: Vehicle Interior Section: Heating/Air Conditioning
Model Year: 2008 Model: Sequoia Doc ID: RM000002VX6004X
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM: TERMINALS OF ECU (2008 Sequoia)

TERMINALS OF ECU

1. CHECK AIR CONDITIONING AMPLIFIER



(a) Disconnect the H24, H67 and z13 air conditioning amplifier connectors.

(b) Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol)

Wiring Color

Terminal Description

Condition

Specified Condition

H24-1 (IG+) - Body ground

P - Body ground

Ignition power supply

Ignition switch ON

11 to 14 V

Ignition switch off

Below 1 V

H24-14 (GND) - Body ground

W-B - Body ground

Ground

Always

Below 1 Ω

H24-21 (B) - Body ground

R - Body ground

Battery power source

Always

11 to 14 V

H67-20 (RGND) - Body ground

W-B - Body ground

Ground

Always

Below 1 Ω

H67-24 (+B2) - Body ground

LG - Body ground

Battery power source

Always

11 to 14 V

If the result is not as specified, there may be a malfunction on the wire harness side.

(c) Reconnect the H24, H67 and z13 air conditioning amplifier connectors.

(d) Measure the voltage and resistance according to the value(s) in the table below.

HINT:

Check from the rear of the connector with it connected to the air conditioning amplifier.

Terminal No. (Symbol)

Wiring Color

Terminal Description

Condition

Specified Condition

H24-5 (TAM) - H24-13 (SG-2)

V - G

A/C ambient temperature sensor signal

Ignition switch ON at 25°C (77°F)

1.35 to 1.75 V

Ignition switch ON at 40°C (104°F)

0.9 to 1.2 V

H24-8 (LOCK) - H24-13 (SG-2)

SB - G

A/C compressor lock sensor signal

Engine is running

Blower switch LO

A/C switch ON

Pulse generation

(see waveform 1)

H24-9 (PRE) - Body ground

Y - Body ground

A/C pressure sensor signal

Refrigerant pressure: normal

0.5 to 4.8355 V

H24-10 (S5-3) - Body ground

R - Body ground

Power supply for presser sensor

Ignition switch ON

4.5 to 5.5 V

H24-11 (CANH) - H24-14 (GND)

B - W-B

Hi-level CAN bus line

Ignition switch ON

Pulse generation

(see waveform 2)

H24-12 (CANL) - H24-14 (GND)

W - W-B

Lo-level CAN bus line

Ignition switch ON

Pulse generation

(see waveform 3)

H24-13 (SG-2) - Body ground

G - Body ground

Ground for ambient temperature sensor

Always

Below 1 Ω

H24-17 (AC1) - H24-14 (GND)

B - W-B

Idle-up request signal

Engine idling

Magnet Clutch is not engaged

11 to 14 V

Engine idling

Magnet Clutch is engaged

Below 1 V

H24-18 (MHTR) - H24-14 (GND)

L - W-B

Mirror heater relay drive signal

Mirror heater switch OFF→ON

11 to 14 V → Below 1 V

H24-20 (MGC) - H24-14 (GND)

P - W-B

A/C compressor magnetic clutch operation signal

Ignition switch ON

Blower switch LO

A/C switch OFF

11 to 14 V

Ignition switch ON

Blower switch LO

A/C switch ON

Below 1 V

H24-23 (BLW) - H24-14 (GND)

LG - W-B

Blower motor control signal

Ignition switch ON

Blower switch LO

Pulse generation

(see waveform 4)

H24-27 (ACT) - H24-14 (GND)

L - W-B

A/C compressor magnetic clutch on permit signal

Engine idling → Accelerator pedal depressed (Air conditioning cut signal output when engine load increases rapidly)

11 to 14 V → Below 2 V

H24-29 (TR) - H24-34 (SG-1)

G - B

Room temperature sensor signal

Ignition switch ON

Front side interior temperature: 25°C (77°F)

1.8 to 2.2 V

H24-32 (TSP) - Body ground

L - Body ground

Passenger side solar sensor signal

Ignition switch ON

Solar sensor subjected to electric light

0.8 to 4.3 V

H24-33 (TSD) - Body ground

P - Body ground

Driver side solar sensor signal

Ignition switch ON

Solar sensor subjected to electric light

0.8 to 4.3 V

H24-34 (SG-1) - Body ground

B - Body ground

Ground for room temperature sensor

Always

Below 1 Ω

H24-37 (LIN1) - H24-14 (GND)

SB - W-B

LIN communication signal

Ignition switch ON

Pulse generation

H24-38 (RDEF) - H24-14 (GND)

R - W-B

Defogger relay drive signal

Defogger switch OFF→ON

11 to 14 V → Below 1 V

H24-39 (CFN+) - H24-14 (GND)

V - W-B

Condenser fan relay drive signal

Ignition switch ON

Condenser fan OFF→ON

11 to 14 V → Below 1 V

H24-40 (D) - H24-14 (GND)

GR - W-B

Deicer relay drive signal

Deicer switch OFF→ON

11 to 14 V → Below 1 V

H67-1 (RBUS) - H67-21 (RBUG)

V - G

BUS IC control signal

Ignition switch off → ON

Pulse generation

H67-4 (TEC) - H67-19 (SGND)

R - L

Rear evaporator temperature sensor signal

Ignition switch ON

Evaporator temperature at 0°C (32°F)

1.7 to 2.1 V

H67-6 (SG-5) - Body ground

BR - Body ground

Ground for seat blower switch

Always

Below 1 Ω

H67-7 (SG-6) - Body ground

P - Body ground

Ground for rear room temperature sensor

Always

Below 1 Ω

H67-8 (S5-2) - H67-6 (SG-5)

SB - BR

Power supply for seat blower switch

Ignition switch ON

4.5 to 5.5 V

H67-9 (SHD+) - H67-20 (RGND)

W - W-B

Driver seat blower drive signal

Ignition switch ON

Pulse generation

H67-10 (SHP+) - H67-20 (RGND)

O - W-B

Passenger seat blower drive signal

Ignition switch ON

Pulse generation

H67-13 (RLIN) - H67-20 (RGND)

B - W-B

LIN communication signal

Ignition switch ON

Pulse generation

H67-15 (AD-4) - H67-20 (RGND)

GR - W-B

Driver seat blower switch signal

Ignition switch ON

Driver seat blower switch 0 position

4.5 to 5.5 V

Ignition switch ON

Driver seat blower switch 3 position

Below 1 V

H67-16 (AD-5) - H67-20 (RGND)

W - W-B

Passenger seat blower switch signal

Ignition switch ON

Passenger seat blower switch 0 position

4.5 to 5.5 V

Ignition switch ON

Passenger seat blower switch 3 position

Below 1 V

H67-17 (TR) - H67-7 (SG-6)

L - P

Rear room temperature sensor signal

Ignition switch ON

Rear side interior temperature: 25°C (77°F)

1.8 to 2.2 V

H67-19 (SGND) - Body ground

L - Body ground

Ground for rear evaporator temperature sensor

Always

Below 1 Ω

H67-21 (RBUG) - Body ground

G - Body ground

Ground for BUS IC

Always

Below 1 Ω

H67-22 (BLWH) - H67-20 (RGND)

P - W-B

Blower motor control signal

Ignition switch ON

Blower switch LO

Pulse generation

(see waveform 5)

H67-23 (RBBU) - H67-21 (RBUG)

Y - G

Power supply for BUS IC

Ignition switch off

Below 1 V

Ignition switch ON

11 to 14 V

z13-2 (BUS G) - Body ground

-

Ground for BUS IC

Always

Below 1 Ω

z13-3 (BUS) - z13-2 (BUS G)

-

BUS IC control signal

Ignition switch off → ON

Pulse generation

z13-4 (B BUS) - z13-2 (BUS G)

-

Power supply for BUS IC

Ignition switch off

Below 1 V

z13-4 (B BUS) - z13-2 (BUS G)

-

Ignition switch ON

11 to 14 V

z13-5 (SGA) - Body ground

-

Ground for evaporator temperature sensor

Always

Below 1 Ω

z13-6 (TEA) - z13-5 (SGA)

-

A/C evaporator temperature sensor signal

Ignition switch ON

Evaporator temperature at 0°C (32°F)

1.7 to 2.1 V

z13-6 (TEA) - z13-5 (SGA)

-

Ignition switch ON

Evaporator temperature at 15°C (59°F)

0.7 to 1.3 V

If the result is not as specified, the ECU may have a malfunction.


(e) Waveform 1: Using an oscilloscope

Compressor Lock Signal

Terminal Name

LOCK - SG-2

Tester Range

200 mV/DIV., 10 ms./DIV.

Condition

Engine is running

Blower switch LO

A/C switch ON


(f) Waveform 2 (Reference) : Using an oscilloscope

CAN Communication Signal

Terminal Name

CANH - GND

Tester Range

1 V/DIV., 10 μsec./DIV.

Condition

Ignition switch ON

HINT:

The waveform varies depending on the CAN communication signal.


(g) Waveform 3 (Reference) : Using an oscilloscope

CAN Communication Signal

Terminal Name

CANL - GND

Tester Range

1 V/DIV., 10 μsec./DIV.

Condition

Ignition switch ON

HINT:

The waveform varies depending on the CAN communication signal.


(h) Waveform 4 : Using an oscilloscope

Blower Motor Control Signal

Terminal Name

BLW - GND

Tester Range

1 V/DIV., 500 μsec./DIV.

Condition

Ignition switch ON

Blower switch LO

HINT:

When the blower level is increased, the duty ratio changes accordingly.


(i) Waveform 5 : Using an oscilloscope

Blower Motor Control Signal

Terminal Name

BLWH - RGND

Tester Range

1 V/DIV., 500 μsec./DIV.

Condition

Ignition switch ON

Blower switch LO

HINT:

When the blower level is increased, the duty ratio changes accordingly.

2. CHECK INTEGRATION CONTROL AND PANEL



(a) Disconnect the H45 integration control and panel connector.

(b) Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol)

Wiring Color

Terminal Description

Condition

Specified Condition

H45-16 (IG+) - H45-1 (GND)

P - W-B

Ignition power supply

Ignition switch ON

11 to 14 V

Ignition switch off

Below 1 V

H45-1 (GND) - Body ground

W-B - Body ground

Ground

Always

Below 1 Ω

H45-9 (OFF) - H45-10 (AUTO)

GR - LG

Steering pad switch signal

Always

10 kΩ or higher

Steering pad switch push to AUTO

Below 2.5 Ω

Steering pad switch push to OFF

313 to 345 Ω

Steering pad switch push to TEMP+

950 to 1050 Ω

Steering pad switch push to TEMP-

2955 to 3266 Ω

If the result is not as specified, there may be a malfunction on the wire harness side.

(c) Reconnect the H45 integration control and panel connector.

Measure the voltage according to the value(s) in the table below.

Terminal No. (Symbol)

Wiring Color

Terminal Description

Condition

Specified Condition

H45-3 (STX) - H45-1 (GND)

SB - W-B

LIN communication signal

Ignition switch ON

Pulse generation

If the result is not as specified, the integration control and panel may have a malfunction.

3. CHECK AIR CONDITIONING CONTROL PANEL



(a) Disconnect the S4 air conditioning control panel connector.

(b) Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol)

Wiring Color

Terminal Description

Condition

Specified Condition

S4-1 (IG) - S4-4 (E)

P - W-B

Ignition power supply

Ignition switch ON

11 to 14 V

Ignition switch off

Below 1 V

S4-4 (E) - Body ground

W-B - Body ground

Ground

Always

Below 1 Ω

If the result is not as specified, there may be a malfunction on the wire harness side.

(c) Reconnect the S4 air conditioning control panel connector.

(d) Measure the voltage according to the value(s) in the table below.

Terminal No. (Symbol)

Wiring Color

Terminal Description

Condition

Specified Condition

S4-5 (RLIN) - S4-4 (E)

GR - W-B

LIN communication signal

Ignition switch ON

Pulse generation

If the result is not as specified, the air conditioning control panel may have a malfunction.